■Name: 8500 Twin Tank Control Valve
Features:
●Salt and water savings by using 100% capacity of the tank in service before switching to the second tank
●Regenerates with soft water and keeps system clean for optimum operating efficiency and minimum maintenance
●Regenerates immediately when needed for 24 hours’continuous soft water ●Electronic timer provides quick setup and programming
Options
●Meter-initiated regeneration ●Bypass control valve (BCV) ●No hard water bypass
Valve Specifications
Valve material |
Noryl |
Inlet/Outlet pipe diameter |
3/4″,1″, 1-1/4″ |
Regenerative process |
5 cycles |
Range of flow(0.35MPa Inflow pressure)
Continuous water inflow (0.1MPa drop) |
3.4 m3/h |
Peak water inflow (0.175MPa drop) |
4.31 m3/h |
Cv |
38 |
Back-wash flow (0.175MPa drop) |
0.91 m3/h |
Regeneration
Down/Up flow |
Only down flow |
Program regulation |
All regeneration steps can be accommodation |
Maximum regenerative time |
99 minutes per cycle |
Meter
Accuracy |
0.56-3.4 m3/h±5% |
Capacity options |
0-37.83 m3 |
Main size
Central line diameter |
1.05″O.D. |
Drain line diameter |
1/2″NPT |
Brine line diameter |
1600-3/8″ |
Base diameter |
2-1/2″-8NPSM |
Height from top of tank |
7-1/2″ |
Suited base diameter |
Soften: 6″——12″ |
Additional Information
Regenerative system |
1610 |
Electrical rating |
24V-50,60Hz |
Maximum power |
8.9 W |
Estimated shipping weight |
Motor:15 Ibs |
Pressure |
Designed:2.1MPa
Operating:0.14-0.84MPa |
Operating temperature |
34°-110°F(10°-43°C) |
|