■Name: Fleck 2510 1" Residential Control Valve
Features:
●Fully adjustable, 5-cycle control delivers upflow backwash, downflow brining, slow rinse, rapid rinse, brine refill, and downflow service ●Time-tested, hydraulically-balanced piston, seal and spacer, controls service flow and regeneration ●Non-corrosive, fiber-reinforced polymer construction ●Excellent flow rates (4.3 /h continuous, 5.4 /h peak) ●Backwash capacity handles tanks up to 16" diameter for softener, and filter applications ●Mechanical control (7- or 12-day clock or metered initiated regeneration)
Options
●Backwash filter ●Up-flow regeneration ●Meter-initiated regeneration
●Manual operation ●Environmental cover ●No hard water bypass ●Auxiliary switch
Valve Specifications
Valve material |
Noryl |
Inlet/Outlet pipe diameter |
3/4″,1″or 1-1/4″ |
Regenerative process |
5 Cycles |
Range of flow(0.35MPa Inflow pressure)
Continuous water inflow (0.1MPa drop) |
4.3 m3/h |
Peak water inflow (0.175MPa drop) |
5.4 m3/h |
Cv |
4.8 |
Back-wash flow (0.175MPa drop) |
3.86 m3/h |
Regeneration
Down/Up flow |
Only down flow |
Program regulation |
All regeneration steps can be accommodation |
Maximum regenerative t
Mechanical controller
SE controller
ET controller |
Motor control:164 per cycle
SE control:0-99 minutes
ET control:0-999.9 minutes |
Meter
Accuracy |
0.057-3.4 m3/h±5% |
Capacity options |
Standard:0.47-8 m3
Extended:2.3-40 m3
SE: 0-37.85 m3
ET: 0-37852.11 m3 |
Main size
Central line diameter |
1″(1.05″)O.D. |
Drain line diameter |
1/2″O.D. |
Brine line diameter |
1600-3/8″ 1650-3/8″ |
Base diameter |
2-1/2″-8NPSM |
Height from top of tank |
7-1/2″ |
Suited base diameter |
Soften: 6″—16″
Except filter:10GPM:8″—16″ |
Additional Information
Regenerative system |
1610 |
Electrical rating |
24V,110V,220V-50,60Hz |
Maximum power |
72W |
Estimated shipping weight |
Time clock:7 Ibs Metered valve:10 Ibs |
Pressure |
Designed:2.1MPa Operating:0.14-0.84MPa |
Operating Temperature |
34°-110°F(10°-43°C) |
|