一、MICRONIX-EDI
Model |
MX-300 |
MX-200 |
MX-100 |
MX-50 |
Size(L*W*H) |
720×690×320 |
590×690×320 |
400×690×320 |
320×690×320 |
Strong water chamber filling resin |
√ |
√ |
√ |
√ |
Working voltage(DCV) |
90~140 |
50~110 |
20~100 |
15~40 |
Design voltage(DCV) |
≤170 |
≤125 |
≤125 |
≤60 |
Working current(DCA) |
2~5 |
2~5 |
2~5 |
2~5 |
设计电流(DCA) |
8 |
8 |
8 |
8 |
Water capacity(m3/h) |
2.6~4.5 |
1.5~2.5 |
0.8~1.5 |
0.3~0.75 |
Maximum Water capacity(m3/h) |
4.5 |
2.8 |
1.6 |
0.8 |
Recovery(%) |
90~95 |
90~95 |
90~95 |
85~95 |
Waterproduction resistivity MΩ.cm |
≥16 |
≥16 |
≥16 |
≥16 |
Inlet pressure(Mpa) |
0.2~0.5 |
0.2~0.5 |
0.2~0.5 |
0.2~0.5 |
Maximum pressure(Mpa) |
0.7 |
0.7 |
0.7 |
0.7 |
Freshwater/water production takeover specifications |
DN25 |
DN25 |
DN25 |
DN25 |
Strong water into/row over specifications |
DN15 |
DN15 |
DN15 |
DN15 |
二、EDI Product water quality
● Resistivity Resistivity:16~18.2 MΩ.cm
●SiO2:5~20ppb
●PH:6.5~7.5
三、EDI ingoing water quality requirements
water |
RO Water production,conductivity:≤20uS/cm 。 Best conductivity:2-1020uS/cm,Maximum conductivity≤50uS/cm |
PH |
6~8 |
temperature |
5℃~38℃ |
Feed water pressure |
0.2~0.6Mpa |
hardness |
<0.5ppm(以CaCO3计) |
organic |
TOC<0.5ppm,Suggest cannot be detected |
oxidant |
Active chlorine(CL2)<0.05ppm,Suggest cannot be detected;(O3)<0.02ppm,Suggest cannot be detected |
Heavy metal ions |
<0.01ppm Fe、Mn、Work sex metal ions |
Si |
<0.05ppm,(以SiO2计) |
CO2 |
When CO2 content than the 5ppm when, can add alkali adjust PH |
particles |
≤1um |
|