Model:ZR4 double tank top mounted softening valve
Characteristics of Performance
1、Microcomputer planar valve; non-wear sealing; cutting off the inflow when shifting location; exerting no influence on the quality of water;
2、Floating bed ion switch; backflow regeneration; double pots working alternately; suitable for softening water at high degree of hardness;
3、Even if the pressure of inflow is 0.05MPa, the equipments can still absorb salt and work normally;
4、There are two modes to choose from (flow pattern and time mode); Users can set parameters according to the hardness of raw water and the field conditions; The consumption of salt is low;
5、 Chinese(or English) operating interface; state memory function of cutting off the electricity and water;
6、 The equipment can coordinate with the liquid level switch and automatically turn itself on and off.
Automatic water softener configuration and parameters (reference)
Water output and raw water hardness |
≤3T/h;≤8mmol/L |
≤4T/h;≤12mmol/L |
≤5T/h;≤15mmol/L |
Rated operating pressure |
0.08MPa |
0.15MPa |
0.20MPa |
Pressure of water Input |
≤0.4MPa |
Running velocity |
15-55 m/hr |
Regenerant consumption |
1:1.4 or 82g/mol |
Power supply and power consumption |
AC 220V;power consumption 0.03kw |
Soften the hard residue |
≤0.03mmol/L |
Salt valve |
YF300(Water interception, water protection, air check) |
Own use of water rate |
≤5%(and the hardness of raw water) |
Exchange tank(Opening 2.5"-8UN) |
2-Φ250×1350 |
2-Φ300×1650 |
2-Φ350×1650 |
Brine tank Capacity |
100L |
200L |
The amount of resin filling |
90%-95% of the tank |
Station parameter |
Half period water output (T) |
30﹡÷raw water hardness (mmol/L) |
50﹡÷raw water hardness (mmol/L) |
70﹡÷raw water hardness (mmol/L) |
Regeneration time (minutes) |
10 |
15 |
20 |
Cleaning time (minutes) * |
10 |
12 |
15 |
Conditions of Usage
1、It has to be guaranteed that there must be 90% filling rate of resin for the floating bed.
2、Water temperature: 0 ° C ~ 45 ° C ; Turbidity (FTU):≤2 ; Ferric ions:≤0.3mg/L ;Suspended substance:≤5mg/L ;
3、The overall amount of salt contained in the inflow: ≤1200mg/L;
4、Hardness (at 1/2CaCo3): ≤15mmol/L;
5、The environmental temperature for the equipments should be kept between 0 °C~50 °C
|